Review




Structured Review

Elekta leksell frame
Leksell Frame, supplied by Elekta, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/leksell+frame/frame+leksell+stereotactic/pm42240877-42-5-7
Average 86 stars, based on 1 article reviews
leksell frame - by Bioz Stars, 2026-09
86/100 stars

Images

Related Articles

Computed Tomography:

Article Title: Robot-assisted versus frame-based stereoelectroencephalography (sEEG) electrode implantation in drug-resistant epilepsy: a meta-analysis of accuracy, efficiency, and safety
Article Snippet: Machetanz 2021 , RC , 2017 to 2020 , Germany , - , Radionics Brown-Roberts-Wells (BRW) Frame , Supine , High-resolution T1-weighted MRI. If MRI wasn't available, CT was done , NA , ROSA One, Zimmer Biomet; robot group , The patient was placed supine, and the patient’s head was fixed in a Mayfield skull clamp and coupled to the robot , High-resolution T1-weighted MRI. If MRI wasn't available, CT was done , NA , Implantation of insular electrodes via AOA or POA was safe and efficient without loss of accuracy despite longer trajectories, and outcomes were comparable between frame-based and robot-assisted sEEG. .. Zheng 2021 , RC , 2018–2019 , China , Skin-to-skin surgical time (from first incision to closure) , Leksell frame (Elekta, Sweden) , Supine , CT scan , Sinovation, 0.8 mm diameter , SINO (Sinovation, Beijing, China) , Supine , CT scan , Sinovation, 0.8 mm diameter , Robot-assisted sEEG was significantly more efficient than frame-based sEEG while maintaining comparable safety and effectiveness. .. Bourdillon 2019 , RC , 2012–2017 , France , Frame installation to frame removal , Talairach frame , NA , MRI performed within 24 , Microdeep depth electrodes, 0.8 diameter , Neuromate robot (Renishaw PLC) , NA , MRI performed within 24 , Microdeep depth electrodes, 0.8 diameter , Robotic sEEG with intraoperative 3D angiography provided superior accuracy to the Talairach approach and highlighted a potential safety advantage over MRI-based planning.

Article Title: Molecular insights into prognostic model for meningiomas treated with stereotactic radiosurgery: negative impacts of 1q gain on tumor control and survival.
Article Snippet: The procedures for single-fraction and hypofractionated SRS using a Leksell Gamma Knife (Elekta Instruments, Stockholm, Sweden) are described in our previous studies [17, 44]. .. After head fixation using a Leksell frame (Elekta Instruments) for single-fraction SRS, stereotactic imaging (magnetic resonance imaging [MRI] between January 1998 and January 2018, and cone-beam computed tomography [CT] thereafter) was performed to obtain precise three-dimensional coordinates. .. For hypofractionated SRS, a thermoplastic mask (Icon Mask Nanor; Elekta Instruments) and cushion (Icon Patient Cushion Klarity; Elekta Instruments) were used for head fixation, and stereotactic imaging was obtained using cone-beam CT in the same fashion as single-fraction SRS.

Article Title: Molecular insights into prognostic model for meningiomas treated with stereotactic radiosurgery: negative impacts of 1q gain on tumor control and survival
Article Snippet: The procedures for single-fraction and hypofractionated SRS using a Leksell Gamma Knife (Elekta Instruments, Stockholm, Sweden) are described in our previous studies [ , ]. .. After head fixation using a Leksell frame (Elekta Instruments) for single-fraction SRS, stereotactic imaging (magnetic resonance imaging [MRI] between January 1998 and January 2018, and cone-beam computed tomography [CT] thereafter) was performed to obtain precise three-dimensional coordinates. .. For hypofractionated SRS, a thermoplastic mask (Icon Mask Nanor; Elekta Instruments) and cushion (Icon Patient Cushion Klarity; Elekta Instruments) were used for head fixation, and stereotactic imaging was obtained using cone-beam CT in the same fashion as single-fraction SRS.

Magnetic Resonance Imaging:

Article Title: Clinical outcomes and anti-inflammatory mechanisms of nucleus basalis of Meynert deep brain stimulation in Alzheimer’s disease
Article Snippet: .. The surgical target was localized 7 mm posterior to the anterior commissure (AC), 7 mm inferior to the AC-PC line, and 25 mm lateral to the midline, guided by T2-weighted MRI and a Leksell frame (Elekta Instrument AB). ..

Article Title: Molecular insights into prognostic model for meningiomas treated with stereotactic radiosurgery: negative impacts of 1q gain on tumor control and survival.
Article Snippet: The procedures for single-fraction and hypofractionated SRS using a Leksell Gamma Knife (Elekta Instruments, Stockholm, Sweden) are described in our previous studies [17, 44]. .. After head fixation using a Leksell frame (Elekta Instruments) for single-fraction SRS, stereotactic imaging (magnetic resonance imaging [MRI] between January 1998 and January 2018, and cone-beam computed tomography [CT] thereafter) was performed to obtain precise three-dimensional coordinates. .. For hypofractionated SRS, a thermoplastic mask (Icon Mask Nanor; Elekta Instruments) and cushion (Icon Patient Cushion Klarity; Elekta Instruments) were used for head fixation, and stereotactic imaging was obtained using cone-beam CT in the same fashion as single-fraction SRS.

Article Title: Molecular insights into prognostic model for meningiomas treated with stereotactic radiosurgery: negative impacts of 1q gain on tumor control and survival
Article Snippet: The procedures for single-fraction and hypofractionated SRS using a Leksell Gamma Knife (Elekta Instruments, Stockholm, Sweden) are described in our previous studies [ , ]. .. After head fixation using a Leksell frame (Elekta Instruments) for single-fraction SRS, stereotactic imaging (magnetic resonance imaging [MRI] between January 1998 and January 2018, and cone-beam computed tomography [CT] thereafter) was performed to obtain precise three-dimensional coordinates. .. For hypofractionated SRS, a thermoplastic mask (Icon Mask Nanor; Elekta Instruments) and cushion (Icon Patient Cushion Klarity; Elekta Instruments) were used for head fixation, and stereotactic imaging was obtained using cone-beam CT in the same fashion as single-fraction SRS.

Imaging:

Article Title: Molecular insights into prognostic model for meningiomas treated with stereotactic radiosurgery: negative impacts of 1q gain on tumor control and survival.
Article Snippet: The procedures for single-fraction and hypofractionated SRS using a Leksell Gamma Knife (Elekta Instruments, Stockholm, Sweden) are described in our previous studies [17, 44]. .. After head fixation using a Leksell frame (Elekta Instruments) for single-fraction SRS, stereotactic imaging (magnetic resonance imaging [MRI] between January 1998 and January 2018, and cone-beam computed tomography [CT] thereafter) was performed to obtain precise three-dimensional coordinates. .. For hypofractionated SRS, a thermoplastic mask (Icon Mask Nanor; Elekta Instruments) and cushion (Icon Patient Cushion Klarity; Elekta Instruments) were used for head fixation, and stereotactic imaging was obtained using cone-beam CT in the same fashion as single-fraction SRS.

Article Title: Molecular insights into prognostic model for meningiomas treated with stereotactic radiosurgery: negative impacts of 1q gain on tumor control and survival
Article Snippet: The procedures for single-fraction and hypofractionated SRS using a Leksell Gamma Knife (Elekta Instruments, Stockholm, Sweden) are described in our previous studies [ , ]. .. After head fixation using a Leksell frame (Elekta Instruments) for single-fraction SRS, stereotactic imaging (magnetic resonance imaging [MRI] between January 1998 and January 2018, and cone-beam computed tomography [CT] thereafter) was performed to obtain precise three-dimensional coordinates. .. For hypofractionated SRS, a thermoplastic mask (Icon Mask Nanor; Elekta Instruments) and cushion (Icon Patient Cushion Klarity; Elekta Instruments) were used for head fixation, and stereotactic imaging was obtained using cone-beam CT in the same fashion as single-fraction SRS.

other:

Article Title: Is it safe to have Deep Brain Stimulation after MRI-guided focused ultrasound ablation? A report of three cases and review of literature.
Article Snippet: In brief, with indirect targeting of the Vim, using the Leksell frame (Elekta, Sweden), surgery is performed with the patient awake with fluoroscopy guidance.

Article Title: Quantitative and Comparative Analysis of Dream Content in Parkinson's Disease Patients Undergoing Deep Brain Stimulation: A Pilot Study.
Article Snippet: On the day of surgery, a Leksell frame (Elekta, Stockholm, Sweden) was secured to the patient’s 97 head under local anesthesia.

Article Title: Is It Safe to Have Deep Brain Stimulation after MRI-Guided Focused Ultrasound Ablation? A Report of Three Cases and Review of Literature
Article Snippet: In brief, with indirect targeting of the Vim, using the Leksell frame (Elekta, Sweden), surgery is performed with the patient awake with fluoroscopy guidance.



Similar Products

86
Elekta leksell frame
Leksell Frame, supplied by Elekta, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/leksell+frame/frame+leksell+stereotactic/pm42240877-42-5-7
Average 86 stars, based on 1 article reviews
leksell frame - by Bioz Stars, 2026-09
86/100 stars
  Buy from Supplier

86
Elekta leksell arc frame
Leksell Arc Frame, supplied by Elekta, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/leksell+frame/frame+leksell+stereotactic/pm42243171-172-19-21
Average 86 stars, based on 1 article reviews
leksell arc frame - by Bioz Stars, 2026-09
86/100 stars
  Buy from Supplier

86
Elekta stereotactic leksell head frame
Stereotactic Leksell Head Frame, supplied by Elekta, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/leksell+frame/frame+leksell+stereotactic/10__3171_slash_case26184-44-7-11
Average 86 stars, based on 1 article reviews
stereotactic leksell head frame - by Bioz Stars, 2026-09
86/100 stars
  Buy from Supplier

86
Elekta leksell g stereotactic frame
Leksell G Stereotactic Frame, supplied by Elekta, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/leksell+frame/frame+leksell+stereotactic/pmc13207932-81-12-15
Average 86 stars, based on 1 article reviews
leksell g stereotactic frame - by Bioz Stars, 2026-09
86/100 stars
  Buy from Supplier

86
Elekta leksell stereotactic frame
Leksell Stereotactic Frame, supplied by Elekta, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/leksell+frame/frame+leksell+stereotactic/pm42151639-60-9-14
Average 86 stars, based on 1 article reviews
leksell stereotactic frame - by Bioz Stars, 2026-09
86/100 stars
  Buy from Supplier

86
Elekta leksell g frame system
Surgical workflow for stereoelectroencephalography (sEEG) implantation. (A) Preoperative trajectory planning based on cranial magnetic resonance imaging. (B) Two-piece slotted cannula (Ad-Tech Medical Instrument Corporation, USA) with blunt-tipped stylet. (C) Multicontact depth electrode (Ad-Tech Medical Instrument Corporation, USA) with flexible stylet. (D) After disinfection and draping, the <t>Leksell</t> <t>G</t> <t>frame</t> (Elekta AB, Stockholm, Sweden) was mounted in a sagittal posterior position. (E) Electrode insertion along the planned trajectory. (F) Electrodes were secured at the skin level with a single stitch.
Leksell G Frame System, supplied by Elekta, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/leksell+frame/frame+leksell+stereotactic/pmc13046494-50-36-39
Average 86 stars, based on 1 article reviews
leksell g frame system - by Bioz Stars, 2026-09
86/100 stars
  Buy from Supplier

86
Elekta leksell g frame
Surgical workflow for stereoelectroencephalography (sEEG) implantation. (A) Preoperative trajectory planning based on cranial magnetic resonance imaging. (B) Two-piece slotted cannula (Ad-Tech Medical Instrument Corporation, USA) with blunt-tipped stylet. (C) Multicontact depth electrode (Ad-Tech Medical Instrument Corporation, USA) with flexible stylet. (D) After disinfection and draping, the <t>Leksell</t> <t>G</t> <t>frame</t> (Elekta AB, Stockholm, Sweden) was mounted in a sagittal posterior position. (E) Electrode insertion along the planned trajectory. (F) Electrodes were secured at the skin level with a single stitch.
Leksell G Frame, supplied by Elekta, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/leksell+frame/frame+leksell+stereotactic/pmc13046494-67-9-11
Average 86 stars, based on 1 article reviews
leksell g frame - by Bioz Stars, 2026-09
86/100 stars
  Buy from Supplier

Image Search Results


Surgical workflow for stereoelectroencephalography (sEEG) implantation. (A) Preoperative trajectory planning based on cranial magnetic resonance imaging. (B) Two-piece slotted cannula (Ad-Tech Medical Instrument Corporation, USA) with blunt-tipped stylet. (C) Multicontact depth electrode (Ad-Tech Medical Instrument Corporation, USA) with flexible stylet. (D) After disinfection and draping, the Leksell G frame (Elekta AB, Stockholm, Sweden) was mounted in a sagittal posterior position. (E) Electrode insertion along the planned trajectory. (F) Electrodes were secured at the skin level with a single stitch.

Journal: Frontiers in Neurology

Article Title: Determinants of accuracy in frame-based stereoelectroencephalography: the role of experience, workflow, and selective use of guiding devices

doi: 10.3389/fneur.2026.1796582

Figure Lengend Snippet: Surgical workflow for stereoelectroencephalography (sEEG) implantation. (A) Preoperative trajectory planning based on cranial magnetic resonance imaging. (B) Two-piece slotted cannula (Ad-Tech Medical Instrument Corporation, USA) with blunt-tipped stylet. (C) Multicontact depth electrode (Ad-Tech Medical Instrument Corporation, USA) with flexible stylet. (D) After disinfection and draping, the Leksell G frame (Elekta AB, Stockholm, Sweden) was mounted in a sagittal posterior position. (E) Electrode insertion along the planned trajectory. (F) Electrodes were secured at the skin level with a single stitch.

Article Snippet: After approval from the institutional review board of Ludwig Maximilians University of Munich (25-0543), the patient database of the Department of Neurosurgery was retrospectively searched for all consecutive patients who underwent stereoelectroencephalography (sEEG) implantation using the Leksell G-frame system (Elekta AB, Stockholm, Sweden) between September 2021 and May 2025.

Techniques: Magnetic Resonance Imaging

Surgical workflow for stereoelectroencephalography (sEEG) implantation. (A) Preoperative trajectory planning based on cranial magnetic resonance imaging. (B) Two-piece slotted cannula (Ad-Tech Medical Instrument Corporation, USA) with blunt-tipped stylet. (C) Multicontact depth electrode (Ad-Tech Medical Instrument Corporation, USA) with flexible stylet. (D) After disinfection and draping, the Leksell G frame (Elekta AB, Stockholm, Sweden) was mounted in a sagittal posterior position. (E) Electrode insertion along the planned trajectory. (F) Electrodes were secured at the skin level with a single stitch.

Journal: Frontiers in Neurology

Article Title: Determinants of accuracy in frame-based stereoelectroencephalography: the role of experience, workflow, and selective use of guiding devices

doi: 10.3389/fneur.2026.1796582

Figure Lengend Snippet: Surgical workflow for stereoelectroencephalography (sEEG) implantation. (A) Preoperative trajectory planning based on cranial magnetic resonance imaging. (B) Two-piece slotted cannula (Ad-Tech Medical Instrument Corporation, USA) with blunt-tipped stylet. (C) Multicontact depth electrode (Ad-Tech Medical Instrument Corporation, USA) with flexible stylet. (D) After disinfection and draping, the Leksell G frame (Elekta AB, Stockholm, Sweden) was mounted in a sagittal posterior position. (E) Electrode insertion along the planned trajectory. (F) Electrodes were secured at the skin level with a single stitch.

Article Snippet: All implantations were performed under general anesthesia using the Leksell G-frame (Elekta AB, Stockholm, Sweden).

Techniques: Magnetic Resonance Imaging